EV XShield — EV Fire Spread Prevention System Singapore

SKU:

Fiready Pte Ltd introduces the EV XShield EV Fire Spread Prevention System — a fixed under-vehicle water spray suppression system engineered specifically for electric vehicle charging bays and EV parking zones in Singapore. When an EV battery fire is detected, EV XShield automatically activates water spray nozzles positioned directly beneath the vehicle — cooling the battery at the source and preventing fire from spreading to adjacent vehicles until SCDF firefighters arrive.

  • Purpose-built for EV carpark fire safety — not a modified conventional sprinkler
  • Dual detection — linear heat detector (primary) + flame detector (optional)
  • Under-vehicle water spray — targets the battery source, not just the top of the vehicle
  • Automatic and manual activation — operates without human intervention
  • Utilises existing sprinkler water supply — no separate water tank required
  • TÜV SÜD PSB-registered fire and safety services contractor

 

The EV Fire Challenge in Singapore’s Carparks

Singapore’s electric vehicle adoption is accelerating rapidly. As of March 2026, approximately 30,500 EV charging points had been deployed across Singapore, with a national target of 60,000 by 2030. More than 90% of HDB carparks were equipped with EV charging points by December 2025. As charging infrastructure expands across condominiums, commercial buildings, industrial facilities and HDB estates, the fire safety implications of EV batteries in enclosed carparks demand serious attention.

⚠️ Why EV Battery Fires Are Different

EV fires are rare — but when they happen in an enclosed carpark, they are significantly harder to manage than conventional vehicle fires. The lithium-ion battery sits beneath the vehicle and can reach extremely high temperatures during thermal runaway. Conventional overhead sprinklers cannot effectively reach the fire source from above. In underground and multi-storey carparks, fire truck access is limited. And EV battery fires can re-ignite after visible flames are suppressed — requiring sustained cooling at the source.

Four Current Challenges for EV Charging and Parking Areas

01) Battery Fire Risk — Thermal Runaway

Lithium-ion battery thermal runaway creates a cascading failure across battery cells — producing extreme heat, fire and toxic gases that are difficult to control.

02) Electrical Hazards

Faulty wiring, overheating or short circuits at charging stations can cause sparks that trigger battery fires — particularly during high-voltage fast charging.

03) Facility and Infrastructure Damage

Charging stations and EV parking bays are often in underground carparks or enclosed facilities where fire spread to adjacent vehicles and building structure is a serious risk.

04) User and Public Safety

Without early detection and automatic suppression, occupants of underground carparks may not have sufficient time to evacuate safely when an EV fire starts.

Why Conventional Fire Systems Are Insufficient for EV Carparks

Conventional Overhead Sprinklers

  • ✗ Spray water from above — cannot reach under-vehicle battery pack
  • ✗ Limited effectiveness in underground carparks with restricted fire truck access
  • ✗ Cannot address thermal runaway re-ignition
  • ✗ Not designed for EV battery source fires

 EV XShield Under-Vehicle System

  •  Spray water from floor level directly under the vehicle
  •  Targets the battery pack at the source of thermal runaway
  •  Automatic activation — no fire truck access required in first response
  •  Continuous cooling prevents re-ignition until SCDF arrives

 

What Is EV XShield?

EV XShield is a fixed EV fire spread prevention system installed in the floor of EV parking bays and charging zones. It combines detection (linear heat detector) with an automated water valve system and under-vehicle spray nozzles — providing an integrated, automatic first response to EV battery fires in carparks.

The system is designed to work with the existing indoor sprinkler water supply — no dedicated water storage tank is required, making it practical and cost-effective for retrofitting into existing carparks.

EV XShield is available in two configurations to suit different carpark layouts and requirements:

  • Full Parking Bed System — a complete under-vehicle suppression platform installed across the full parking bay (5,000 × 2,300 × 63mm) with 8 cooling nozzles per bay delivering 240 LPM at 3K
  • One Nozzle EV Car Fire System — a compact single-rail unit (395 × 3,256 × 52mm) with integrated linear heat detector, nozzles and valve — suitable for individual EV charging spots and narrower installations. Delivers 300 LPM at 3K via bronze nozzles

 

How EV XShield Works — Step by Step

1) Detection — A linear heat detector installed in the parking bed senses the elevated temperature from an EV battery fire. This is the primary detection trigger.

2) Activation — The fire signal triggers the alarm panel and automatically opens the main electric valve (M.O.V) connected to the building’s sprinkler water supply.

3) Isolation — The individual electric ball valve for the specific affected parking bay opens — ensuring only the affected bay is activated, not the entire carpark.

4) Discharge — Water is sprayed upward from cooling nozzles positioned beneath the vehicle, directly onto the underside of the EV and the battery pack. The nozzle design provides inside spray up to 110° and outside spray up to 160° for maximum coverage.

5) Suppression — The water spray reduces heat, suppresses fire and helps prevent fire from spreading to adjacent vehicles and carpark structure.

6) Stabilisation — Cooling continues automatically until SCDF firefighters arrive and take control. If automatic detection does not activate, a facility manager can manually operate the electric valves via the emergency manual control panel.

System Configuration and Components

The EV XShield system consists of the following integrated components:

Component Function Specification
Linear Heat Detector Primary fire detection — installed in the parking bed floor Continuous line detector running length of parking bay
Alarm Panel Receives fire signal and activates system Integrated with building fire alarm system
Manual Control Panel Allows manual override activation by facility manager Emergency button for each zone
Main Electric Valve (M.O.V) Opens water supply to the system on fire signal SUS material, 32A, DC24V
Individual Electric Ball Valve Opens water to specific affected parking bay only Secondary valve — zone isolation
Under-Vehicle Nozzles Discharges cooling water beneath the vehicle onto the battery Bronze nozzle — 3K, 150 LPM (full bed) or 300 LPM (one-nozzle system)
Piping System Connects water supply to nozzles SUS pipe 60×30mm; piping line 65A steel
Auto Drip Valve Prevents water pooling in pipe during standby Automatic drainage when system is not activated
Electric Terminal Box Central electrical connection point for system wiring Located at parking bay perimeter

EV XShield Technical Specifications

Full Parking Bed System

Item Specification
System size 5,000 × 2,300 × 63mm (parking line width 150mm with stoppers)
Optional sizes 2,100mm and 2,200mm width options available
Operation method Under cooling nozzle × 8 EA — 3K, 240 LPM
Installation method Chemical anchor bolt M12 for parking line frame; Nut M12 for parking bed upper plate
Installation location EV charging facilities and zones in indoor/underground and outdoor parking lots
Water supply Utilises existing sprinkler system

One Nozzle EV Car Fire System

Item Specification
System size 395 × 3,256 × 52mm
Working method Under water spray — 3K, 300 LPM
Installation location EV charging spot or parking spot
Water supply Existing sprinkler system
Nozzle material Bronze
M.O.V specification SUS, 32A, DC24V
Pipe specification SUS 60×30mm
Cover material Steel 3.0t
Piping line Steel 65A
Nozzle spray coverage Inside spray up to 110° / Outside spray up to 160°
Installation method Anchor bolt M12 × 12 EA; Nozzle cover bolt M10 × 3 EA; Pipe cover nut M12 × 6 EA

Who Needs EV XShield in Singapore?

Any premises in Singapore with EV charging bays or EV parking zones should consider the EV XShield system as part of a comprehensive EV fire safety approach:

🏠 Condominiums (MCST)

🏢 Commercial buildings

🏦 HDB carparks

🏭 Industrial facilities

🏨 Hotels and serviced apartments

🛒 Shopping malls

🚐 Fleet depots and bus parks

📦 Logistics and warehousing

🏥 Hospitals and healthcare facilities

The EV XShield system is particularly important for underground and multi-storey enclosed carparks where fire truck access is restricted and fire spread to adjacent vehicles poses the highest risk.

Frequently Asked Questions — EV Fire Suppression System Singapore

What is an EV fire spread prevention system?

An EV fire spread prevention system is a fixed fire suppression system installed beneath EV parking bays in carparks and charging zones. When a fire is detected, the system automatically activates water spray nozzles positioned under the vehicle — cooling the battery pack at the source and preventing fire from spreading to adjacent vehicles. The EV XShield system uses a linear heat detector as primary detection and a flame detector as an optional secondary confirmation before discharging water.

Why are EV fires harder to manage in carparks?

EV battery fires are harder to manage in enclosed carparks because the lithium-ion battery sits beneath the vehicle — conventional overhead sprinklers cannot effectively reach the fire source. In underground and multi-storey carparks, access for fire trucks is limited. EV battery fires can also re-ignite after visible flames are suppressed due to ongoing thermal runaway. An under-vehicle system addresses these challenges directly.

What is thermal runaway in an EV battery?

Thermal runaway occurs when a lithium-ion battery cell overheats and triggers a chain reaction — heat causes adjacent cells to fail in a cascading sequence that can engulf the entire battery pack. Causes include mechanical damage, overcharging, internal short circuits or external heat. Thermal runaway produces extreme temperatures and toxic gases, making rapid cooling at the source critical.

How does the EV XShield system work?

When a linear heat detector in the parking bed senses a fire, the system automatically triggers the main electric valve connected to the sprinkler water supply, opens individual electric ball valves at the affected bay, and discharges water from nozzles positioned beneath the vehicle. The water cools the battery pack and prevents fire spread until firefighters arrive. Facility managers can also activate the system manually if needed.

Does the EV XShield system require a separate water tank?

No. The EV XShield system utilises the existing indoor sprinkler water supply in the building — no separate water storage tank is required. This significantly simplifies installation and reduces cost, particularly for retrofitting into existing carparks.

Can EV XShield be installed in existing carparks?

Yes. The EV XShield system is designed to be retrofittable to existing carparks — including indoor and underground parking areas. Installation uses chemical anchor bolts to secure the parking bed unit to the floor without major structural modification.

Who needs an EV fire suppression system in Singapore?

Any premises with EV charging bays or EV parking zones — including condominiums, HDB carparks, commercial buildings, shopping malls, hotels, industrial facilities, fleet depots and logistics hubs. With more than 90% of HDB carparks equipped with EV charging points by December 2025 and a national target of 60,000 charging points by 2030, EV fire safety is a growing priority for building management across Singapore.

Contact Fiready for EV XShield — EV Fire Spread Prevention System Singapore

Fiready Pte Ltd supplies and installs the EV XShield EV Fire Spread Prevention System in Singapore. Contact us to discuss your EV carpark fire safety requirements and arrange a site consultation.

  • EV XShield Full Parking Bed System — 5,000 × 2,300 × 63mm, 8 nozzles, 240 LPM
  • EV XShield One Nozzle System — 395 × 3,256 × 52mm, 300 LPM
  • Dual detection — linear heat detector + flame detector
  • Automatic and manual activation
  • Utilises existing sprinkler water supply — no water tank required
  • Retrofittable to existing indoor and underground carparks
  • TÜV SÜD PSB-registered fire safety contractor

 

Contact Us: 63223982
Email: mak@fireadysg.com

Related Fire Safety Products and Services

 

Fiready Pte Ltd — EV XShield EV Fire Spread Prevention System Singapore | TÜV SÜD PSB-registered
www.fireadysg.com

 

Add to Enquiry

Related Products

Portable Gas Detector and Calibration Services

Solar Panel Fire Extinguisher Singapore

   

Company Emergency Response Team (CERT) Equipment

We supply a comprehensive range of Company Emergency Response Team (CERT) equipment to support organisations in preparing for fire, medical, and emergency response situations from Tier 1 to Tier 3. Our CERT equipment is suitable for workplaces, commercial buildings, factories, data centres, and industrial facilities, helping teams respond effectively during emergencies while meeting fire safety and workplace requirements. Our solutions are tailored to site needs and can be supplied as individual items or complete CERT equipment packages. CERT Equipment Supplied
  • Self-Contained Breathing Apparatus (Tier 1)
  • Fire extinguishers (various types and sizes)
  • Fire blankets
  • Automated External Defibrillators (AED)
  • First aid kits and trauma supplies
  • Emergency stretchers
  • Protective gloves, helmets, and safety PPE (Tier 2-3)
  • Fireman suit, fireman helmet, gloves and boots (Tier 1)
  • Emergency signage and response accessories
  Scope of Service
  • Certified and industry-approved CERT equipment
  • Equipment selection based on site risk and response needs
  • Optional installation of cabinets, brackets, and storage solutions
  • Equipment familiarisation and usage briefing (upon request)
  Applications Offices | Factories | Warehouses | Data Centres | Commercial Buildings | Industrial Premises Compliance & Readiness
  • Suitable for CERT setup and workplace emergency preparedness
  • Supports SCDF fire safety and emergency response requirements
  • Reliable equipment for drills, training, and real emergency use
  CTA Contact us to discuss your CERT equipment requirements or to customise a complete emergency response kit for your premises.

Wet Chemical Kitchen Suppression System

Supply & Installation for Commercial Kitchen Hoods We provide supply, installation, and commissioning of Wet Chemical Kitchen Fire Suppression Systems designed specifically to protect commercial kitchen hoods, ducts, and cooking appliances. This system is highly effective against cooking oil and grease fires, helping to prevent fire spread and minimise downtime in food service operations. Our solutions are suitable for restaurants, food courts, central kitchens, hotels, cafés, and industrial kitchens, and are designed to meet local fire safety requirements. System Coverage
  • Kitchen exhaust hoods
  • Ducting systems
  • Cooking appliances (woks, fryers, ranges, grills)
  Scope of Service
  • Site survey and system design based on kitchen layout
  • Supply of wet chemical fire suppression system
  • Professional installation of piping, nozzles, and detection lines
  • Integration with gas shut-off and electrical interlock (where applicable)
  • System testing, commissioning, and demonstration
  • As-built drawings and documentation for inspection and audit
  Key Features
  • Rapid fire knockdown and re-ignition prevention
  • Automatic activation with manual override
  • Non-toxic wet chemical agent suitable for food preparation areas
  • Minimal clean-up compared to traditional extinguishing methods
  Applications Restaurants | Food courts | Central kitchens | Hotels | Cafés | Industrial kitchens Compliance & Assurance
  • Installed in accordance with SCDF fire safety requirements
  • Suitable for commercial kitchen fire protection compliance
  • Proper documentation provided for inspections and approvals
  CTA Contact us for supply and installation of wet chemical kitchen suppression systems to protect your commercial kitchen and meet fire safety requirements.

Self-Contained Breathing Apparatus (SCBA)

Supply, Servicing, Refilling & Familiarity Training We provide a complete solution for Self-Contained Breathing Apparatus (SCBA), covering supply, servicing, and familiarity training to support safe operations in smoke-filled, oxygen-deficient, or hazardous environments. Our SCBA solutions are commonly used by Company Emergency Response Teams (CERT) and for FM200 / clean agent protected areas, such as server rooms and critical facilities. SCBA is also commonly used in confined space environment together with portable gas detectors.

Scope of Service

SCBA Supply

  • Supply of reliable SCBA systems for professional use
  • Full face mask with secure seal and clear visibility
  • High-pressure air cylinder with pressure gauge
  • Lightweight harness designed for extended wear
 

SCBA Servicing & Maintenance

  • Visual inspection of mask, harness, and hoses
  • Cylinder pressure and condition checks
  • Regulator and valve function inspection
  • Low-air alarm verification
  • Servicing tags and maintenance records provided
 

SCBA Familiarity Training

  • Basic SCBA familiarisation and safe usage briefing
  • Donning and doffing procedures
  • Understanding air duration and low-air warnings
  • Practical guidance for CERT and emergency response teams
 

Typical Applications

CERT operations | FM200 / clean agent rooms | Server rooms | Data centres | Control rooms | Emergency response scenarios | Confined space works

Compliance & Readiness

  • Supports CERT preparedness and emergency response planning
  • Helps meet fire safety and workplace requirements
  • Ensures SCBA remains operational and ready for use
  • One-stop solution for supply, training, and ongoing maintenance
 

CTA

Contact us for SCBA supply, servicing, and familiarity training to ensure your emergency response team is fully prepared.

AED Singapore – Automated External Defibrillator

Fire Alarm System Supply & Installation | Fire Detection & Alarm Solutions

We provide supply, installation, testing, and commissioning of fire alarm systems to ensure early fire detection and timely evacuation. Our systems are designed to protect life and property by delivering clear audible and visual alerts during a fire emergency. We support a wide range of premises, from commercial buildings and factories to residential developments, with fire alarm solutions tailored to site requirements and regulatory needs. Fire Alarm System Components Supplied
  • Fire Alarm Control Panel
  • Fire Alarm Bells and Sounders
  • Strobe Lights / Visual Alarm Devices
  • Manual Call Points (Break Glass Units)
  • Smoke Detectors
  • Heat Detectors
  • Fire alarm cabling and accessories
  Scope of Service
  • Site survey and system design based on building layout
  • Supply of fire alarm panels and field devices
  • Professional installation and wiring
  • System testing, commissioning, and functional verification
  • Integration with other fire protection systems (where applicable)
  • As-built drawings and documentation for inspections and audits
  Applications Offices | Factories | Warehouses | Retail shops | Schools | Condominiums | Industrial premises Compliance & Assurance
  • Installed in accordance with SCDF fire safety requirements
  • Suitable for fire safety inspections and certification
  • Proper documentation provided upon completion
  CTA Contact us for professional supply and installation of fire alarm systems tailored to your premises.

Fire Hose Reel Supply, Cabinet Installation & Annual Servicing

We provide a complete solution for fire hose reels, including supply, cabinet installation, and annual servicing, ensuring your building’s firefighting system is fully operational and compliant. Fire hose reels are essential for early fire response and are suitable for commercial, industrial, and residential buildings.

Scope of Service

Supply

  • Supply of fire hose reels suitable for various building types
  • High-quality hoses, nozzles, and valves
  • Standard sizes to meet site requirements

Cabinet Installation

  • Supply and installation of fire hose reel cabinets
  • Indoor and outdoor cabinet options
  • Proper mounting, accessibility, and signage

Annual Servicing

  • Visual inspection of hose, nozzle, and cabinet
  • Testing for water flow, pressure, and hose operation
  • Valve checks and leakage inspection
  • Servicing tags and maintenance documentation provided
  • Ensures compliance with SCDF fire safety regulations
 

Applications

Offices | Factories | Warehouses | MCST | Condominiums | Industrial & commercial buildings

Compliance & Assurance

  • Installed and maintained according to SCDF fire safety standards
  • Supports fire certificate renewal and statutory inspections
  • Ensures readiness of firefighting equipment in emergencies

 

CTA

Contact us for supply, cabinet installation, and annual servicing of fire hose reels to ensure your building remains compliant and fire-ready.

Fire Extinguishers Supply, Installation & Servicing | 1kg to 9kg

We supply, install, and service a full range of portable fire extinguishers to suit residential, commercial, and industrial applications. Our extinguishers are designed for quick response and reliable fire suppression, helping to protect life and property while meeting local fire safety requirements. Available in multiple sizes, our extinguishers can be selected based on risk level, coverage area, and regulatory needs. Available Fire Extinguisher Sizes
  • 1kg Fire Extinguisher– Ideal for homes, vehicles, and small offices
  • 2kg Fire Extinguisher– Suitable for residential and light commercial use
  • 3kg Fire Extinguisher– Commonly used in offices and retail shops
  • 4kg Fire Extinguisher– Suitable for commercial and industrial areas
  • 6kg Fire Extinguisher– Standard size for factories and warehouses
  • 9kg Fire Extinguisher– For higher-risk and industrial environments
(Types available subject to application, e.g. dry powder, CO₂, clean agent.) Fire Extinguisher Cabinets & Accessories We also supply fire extinguisher cabinets and accessories for safe storage and clear visibility, suitable for indoor and outdoor installations. Installation & Servicing
  • Professional fire extinguisher installation at designated locations
  • Annual inspection and servicing in accordance with fire safety standards
  • Refilling, replacement, and condition assessment
  • Service tagging and documentation for audits and inspections
  Applications Homes | Offices | Shops | Factories | Warehouses | MCST | Commercial buildings   Compliance & Assurance
  • Fire extinguishers supplied and maintained to relevant safety standards
  • Proper documentation provided for fire safety inspections
  • One-stop solution for supply, installation, and maintenance
  CTA Contact us for fire extinguisher supply, cabinet installation, and professional servicing tailored to your premises.